Schneider Electric LR2K0307: TeSys LRK differential thermal overload relay with a 1.2-1.8A adjustable thermal setting, Class 10A tripping, and built-in phase failure and load unbalance detection for the protection of 3-phase motors rated 0.55kW@400V.
Phase Failure & Load Unbalance Detection
As a differential thermal overload relay, the LR2K0307 detects phase failure and load unbalance in addition to standard thermal overload conditions, tripping the circuit to protect the connected three-phase motor.
Manual Control & Fault Signalling
A thermal adjustment dial sets the trip point across the 1.2-1.8A range, while a manual/automatic reset selector switch lets you choose how the relay recovers after a trip. A test slide switch simulates a tripping event for commissioning checks, a red push-button provides the trip test function, and a blue push-button handles stop and manual reset. A yellow flag indicator shows local trip status, and 2 auxiliary contacts (1NO+1NC) carry fault signalling back to the control circuit (690V AC AC-15 / 250V DC DC-13).
Secure, Tamper-Resistant Settings
The thermal setting dial sits behind a transparent cover that can be locked by sealing, keeping the chosen protection level secure once commissioned.
Flexible Mounting Options
Screw clamp terminal connections allow the relay to connect directly to the bottom terminals of 3-pole contactors LC1K06-K16 for a compact assembly. Alternatively, it can be mounted separately on DIN rail using terminal block LA7K0064 (ordered separately) when panel layout calls for it.
Key Features of the Schneider Electric TeSys LR2K0307 Thermal Overload Relay Include:
- Differential Thermal Overload Relay With Phase Failure & Load Unbalance Detection
- Thermal Setting Range: 1.2-1.8A, Adjustable Via Dial
- Tripping Class: 10A, Conforming To IEC 60947-4-1
- For Protection Of 3-Phase Motors Rated 0.55kW@400V
- Manual Or Automatic Reset Selector Switch
- Test Slide Switch For Simulating A Tripping Event
- Red Push-Button: Trip Test Function; Blue Push-Button: Stop & Manual Reset
- Yellow Flag Trip Indicator For Local Signalling
- 2 Auxiliary Contacts (1NO+1NC) For Remote Fault Signalling, 690V AC AC-15 / 250V DC DC-13
- Settings Protected By A Transparent, Sealable Cover
- Screw Clamp Terminal Connection; Connects Directly To The Bottom Terminals Of 3-Pole Contactors LC1K06-K16
- DIN Rail Mountable (Separate From Contactor) Using Terminal Block LA7K0064 (Ordered Separately)
- Max. Rated Operational Voltage (Ue): 690V
- Rated Insulation Voltage (Ui): 690V, Conforming To IEC 60947
- Rated Impulse Withstand Voltage (Uimp): 6kV
- IP Degree Of Protection: IP2X, Conforming To IEC 60529
- Ambient Air Temperature For Operation: -20°C To 55°C Without Derating
- Height: 58mm
- Width: 45mm
- Depth: 65mm
- Net Weight: 0.145kg
- Multi-Standard Certified (IEC, UL, CSA, CCC, EAC); Green Premium Compliant (RoHS/REACH)
- Warranty: 18 Months