Schneider Electric LRD16: TeSys Deca Thermal Overload Relay with a 9-13A adjustable setting range and Class 10A tripping, for protection of 3-phase motors up to 5.5kW at 400V.
Motor Protection & Fault Detection
This differential thermal overload relay detects phase failure and load unbalance, helping to identify damaging overload conditions on three-phase motors. Two auxiliary contacts (1NO+1NC) provide fault signalling back to the control circuit.
Simple Setup, Secured Settings
A thermal adjustment dial sets the current within the 9-13A range, while a manual/automatic reset selector and a test selector let you simulate a trip before commissioning. Reset and stop push-buttons, plus a flag indicator, are built in. A transparent cover protects the settings and can be lockable by sealing to prevent unauthorised adjustment.
Flexible Mounting
The relay connects directly to the bottom terminals of 3-pole contactors LC1D12, LC1D18, LC1D25, LC1D32 and LC1D38. It can also be mounted separately on DIN rail or by screw fixing using terminal block LAD7B106 (ordered separately). Connections use screw clamp terminals on both the control and power circuits.
Multi-Standard Certification
Certified to IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX INERIS and UKCA, and compliant with EU RoHS and REACH, this thermal overload relay is built for a wide range of industrial and marine motor control and overload contactor applications.
Key Features of the Schneider Electric TeSys LRD16 Thermal Overload Relay Include:
- Differential thermal overload relay for 3-phase motor protection
- Detects phase failure and load unbalance for improved fault detection
- Thermal protection adjustment range: 9-13A
- Tripping class: Class 10A conforming to IEC 60947-4-1
- Tripping threshold: 1.14 ± 0.06 Ir conforming to IEC 60947-4-1
- Phase failure sensitivity: tripping current 130% of Ir on two phases, the third at 0
- Auxiliary contacts: 1NO+1NC for fault signalling
- Manual/automatic reset selector, test selector and stop/reset push-buttons
- Transparent settings cover, lockable by sealing
- Connects directly to contactors LC1D12, LC1D18, LC1D25, LC1D32 and LC1D38
- Mounting: direct attachment under contactor, DIN rail or screw fixing (with LAD7B106 terminal block, ordered separately)
- Connections: screw clamp terminals, tightening torque 1.7N.m
- Rated operational voltage (Ue): 690V AC, 0...400Hz
- Rated insulation voltage (Ui): 690V (IEC), 600V (UL/CSA)
- Ingress protection: IP20 conforming to IEC 60529
- Ambient operating temperature: -20°C to 60°C without derating
- Ambient storage temperature: -60°C to 70°C
- Height: 66mm
- Width: 45mm
- Depth: 70mm
- Weight: 0.124kg
- Standards: EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, GB/T 14048.4, GB/T 14048.5, EN 50495
- Certifications: IEC, UL, CSA, CCC, EAC, BV, RINA, DNV-GL, LROS, ATEX INERIS, UKCA
- Green Premium compliant: RoHS and REACH
- Warranty: 18 months