Schneider Electric TeSys Deca 4NO Auxiliary Contact Block

Product Code LADN40 TE

Available for Delivery only, change to Fast Delivery Service

£17.03

exc VAT

£20.44 : inc VAT

£20.44

inc VAT

£17.03 : exc VAT

Qty:

Schneider Electric LADN40: TeSys Deca 4NO Auxiliary Contact Block with front clip-on mounting and screw clamp terminals, rated up to 690V AC.

Front Clip-On Mounting

This auxiliary contact block fits by front clip-on mounting and is compatible with TeSys D CAD, TeSys D LC1D, TeSys F LC1F, TeSys F CR1F, TeSys Deca CAD and TeSys Deca LC1D contactors and control relays. The 4NO (normally open) instantaneous contact arrangement adds extra switching points to the base device.

Rated Switching Performance

Rated operational voltage is 690V AC (25...400Hz), with operational currents of 6A at 120V AC-15, 1.04A at 690V AC-15, 0.55A at 125V DC-13 and 0.1A at 600V DC-13. A conventional free air thermal current (Ith) of 10A at 60°C and a mechanical durability rating of 30 million cycles are stated for this block, as is an insulation resistance above 10 MOhm.

Screw Clamp Termination

Connection is by screw clamp terminals, accepting 1 or 2 cables from 1mm² to 4mm², flexible or rigid, with or without cable end, tightened to 1.7N.m. This auxiliary contact block carries an IP2X degree of protection and is rated for ambient operation from -5°C to 60°C.

Multi-Standard Certification

This auxiliary contact schneider block is certified to EN/IEC 60947-5-1, GB/T 14048.5, EN 50012, UL 60947-5-1 and CSA C22.2 No 60947-5-1, with product certifications covering CB Scheme, UL, CSA, CCC, EAC and UKCA.

Key Features of the Schneider Electric TeSys Deca LADN40 Auxiliary Contact Block Include:

  • 4NO (Normally Open) Instantaneous Auxiliary Contacts
  • Clip-On Front Mounting; Compatible With TeSys D CAD, D LC1D, F LC1F, F CR1F, Deca CAD And Deca LC1D
  • Rated Operational Voltage: 690V AC (25...400Hz)
  • Rated Operational Current: 6A At 120V AC-15; 1.04A At 690V AC-15; 0.55A At 125V DC-13; 0.1A At 600V DC-13
  • Rated Operation Current Ie At AC-15, 230V: 10A
  • Conventional Free Air Thermal Current (Ith): 10A At 60°C
  • Mechanical Durability: 30 Million Cycles
  • Minimum Switching Current: 5mA; Minimum Switching Voltage: 17V
  • Insulation Resistance: >10 MOhm
  • Ingress Protection: IP2X (IEC 60529)
  • Screw Clamp Terminals, 1–4mm² Flexible Or Rigid Cable, 1 Or 2 Cables, With Or Without Cable End
  • Tightening Torque: 1.7N.m
  • Height: 48mm
  • Width: 44mm
  • Depth: 42mm
  • Weight: 0.05kg
  • Colour: Dark Grey
  • Operating Temperature: -5°C To 60°C; Storage Temperature: -60°C To 80°C
  • Operating Altitude: Up To 3000m
  • Standards: EN/IEC 60947-5-1, GB/T 14048.5, EN 50012, UL 60947-5-1, CSA C22.2 No 60947-5-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ
  • Product Certifications: CB Scheme, UL, CSA, CCC, EAC, UKCA
  • Warranty: 18 Months
Model Number: LADN40
Brand: Schneider Electric
Range: TeSys Deca
Product Type: Auxiliary Contact Block
Range Compatibility: TeSys D CAD, TeSys D LC1D, TeSys F LC1F, TeSys F CR1F, TeSys Deca CAD, TeSys Deca LC1D
Mounting Location: Front
Mounting Method: Front Fastening
Model: Clip-On
Pole Contact Composition: 4NO
Number Of Contacts As Normally Open Contact: 4
Number Of Contacts As Normally Closed Contact: 0
Number Of Contacts As Change-Over Contact: 0
Number Of Fault-Signal Switches: 0
Contacts Operation: Instantaneous
Rated Operational Voltage (Ue): 690V AC 25...400Hz
Rated Operational Current (Ie): 6A at 120V AC-15; 1.04A at 690V AC-15; 0.55A at 125V DC-13; 0.1A at 600V DC-13
Rated Operation Current Ie At AC-15, 230V: 10A
Rated Insulation Voltage (Ui): 690V conforming to IEC 60947-5-1; 600V conforming to UL; 600V conforming to CSA
Conventional Free Air Thermal Current (Ith): 10A (at 60°C)
Standards: EN/IEC 60947-5-1, GB/T 14048.5, EN 50012, UL 60947-5-1, CSA C22.2 No 60947-5-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ
Product Certifications: CB Scheme, UL, CSA, CCC, EAC, UKCA
Irms Rated Making Capacity: 140A AC conforming to IEC 60947-5-1; 250A DC conforming to IEC 60947-5-1
Permissible Short-Time Rating: 100A at 60°C for 1s; 120A at 60°C for 500ms; 140A at 60°C for 100ms
Protection Type: GG Fuse 10A
Mechanical Durability: 30 Mcycles
Minimum Switching Current: 5mA
Minimum Switching Voltage: 17V
Non-Overlap Time: 1.5ms on de-energisation (no overlap between NC and NO contact); 1.5ms on energisation (no overlap between NC and NO contact)
Insulation Resistance: >10 MOhm
Type Of Electric Connection: Screw Connection
Connections - Terminals: Screw clamp terminals, 1 or 2 cables, 1-4mm² flexible or rigid, with or without cable end (also 2 cables 1-2.5mm² flexible with cable end)
Tightening Torque: 1.7N.m (with screwdriver flat Ø6mm, Philips No2, or pozidriv No2)
Height: 48mm
Width: 44mm
Depth: 42mm
Net Weight: 0.05kg
Colour: Dark Grey
Environmental Characteristic: Normal Environment
IP Degree Of Protection: IP2X conforming to IEC 60529
Protective Treatment: TH conforming to IEC 60068
Ambient Air Temperature For Storage: -60°C to 80°C
Ambient Air Temperature For Operation: -5°C to 60°C
Operating Altitude: 3000m
Warranty: 18 Months