Schneider Electric TeSys Deca 4NC Auxiliary Contact Block

Product Code LADN04 TE

Available for Delivery only, change to Fast Delivery Service

£17.03

exc VAT

£20.44 : inc VAT

£20.44

inc VAT

£17.03 : exc VAT

Qty:

Schneider Electric LADN04: TeSys Deca Auxiliary Contact Block with 4 NC contacts, rated 690V AC, for front mounting on TeSys D, TeSys F and TeSys Deca contactors and control relays.

Reliable Switching Over Time

The LADN04 is rated for 30 million mechanical cycles, giving it a long operating life in control circuits that switch frequently. Contact operation is instantaneous, with a non-overlap time of 1.5ms on both energisation and de-energisation between NC and NO contacts, so switching transitions are clearly defined.

Flexible Termination

Screw clamp terminals accept both flexible and rigid cable from 1mm² up to 4mm², with or without cable ends, tightened to 1.7N.m. This lets installers wire the block with the cable type already specified for the panel, using a flat, Phillips No.2 or pozidriv No.2 screwdriver.

Multi-Standard Certification

The block is built to EN/IEC 60947-5-1, GB/T 14048.5, EN 50012, UL 60947-5-1 and CSA C22.2 No 60947-5-1, and carries CB Scheme, UL, CSA, CCC, EAC and UKCA certification. This supports specification on projects where multiple approval marks are required.

Clip-on front mounting fits the block directly to compatible TeSys D (LC1D), TeSys D (CAD), TeSys F (LC1F), TeSys F (CR1F) and TeSys Deca (CAD, LC1D) contactors and control relays.

Key Features of the Schneider Electric TeSys Deca LADN04 Auxiliary Contact Block Include:

  • 4 NC (normally closed) instantaneous auxiliary contacts
  • Clip-on front mounting for TeSys D, TeSys F and TeSys Deca contactors and control relays
  • Rated operational voltage (Ue): 690V AC, 25...400Hz
  • Rated operational current (Ie): 6A at 120V AC-15; 1.04A at 690V AC-15; 0.55A at 125V DC-13; 0.1A at 600V DC-13
  • Rated operating current (Ie) at AC-15, 230V: 10A
  • Rated insulation voltage (Ui): 690V (IEC 60947-5-1); 600V (UL); 600V (CSA)
  • Conventional free air thermal current (Ith): 10A at 60°C
  • Irms rated making capacity: 140A AC; 250A DC
  • Permissible short-time rating: 100A for 1s; 120A for 500ms; 140A for 100ms
  • Mechanical durability: 30 million cycles
  • Minimum switching current: 5mA; minimum switching voltage: 17V
  • Non-overlap time: 1.5ms on energisation and de-energisation
  • Insulation resistance: >10 MOhm
  • Screw clamp terminals accept 1 to 4mm² flexible or rigid cable, with or without cable end; tightening torque 1.7N.m
  • Ingress protection: IP20 (IEC 60529); operating temperature -5°C to 60°C; storage temperature -60°C to 80°C
  • Operating altitude up to 3000m
  • Compliant with EN/IEC 60947-5-1, GB/T 14048.5, EN 50012, UL 60947-5-1, CSA C22.2 No 60947-5-1, IEC 60335-1 Clause 30.2, IEC 60335-2-40 Annex JJ, UL 60335-2-40 Annex JJ
  • Certified to CB Scheme, UL, CSA, CCC, EAC and UKCA
  • Height: 48mm
  • Width: 44mm
  • Depth: 42mm
  • Weight: 0.05kg
  • Colour: Dark grey
  • Warranty: 18 months
Model Number: LADN04
Brand: Schneider Electric
Range: TeSys / TeSys Deca
Product Type: Auxiliary Contact Block
Range Compatibility: TeSys D LC1D, TeSys D CAD, TeSys F LC1F, TeSys F CR1F, TeSys Deca CAD, TeSys Deca LC1D
Mounting Method: Front Fastening
Model: Clip-on
Pole Contact Composition: 4 NC
Number Of Contacts As Normally Closed Contact: 4
Number Of Contacts As Normally Open Contact: 0
Number Of Contacts As Change-Over Contact: 0
Number Of Fault-Signal Switches: 0
Contacts Operation: Instantaneous
Type Of Electric Connection: Screw Connection
Rated Operational Voltage (Ue): 690V AC, 25...400Hz
Rated Operational Current (Ie): 6A at 120V AC-15; 1.04A at 690V AC-15; 0.55A at 125V DC-13; 0.1A at 600V DC-13
Rated Operating Current (Ie) At AC-15, 230V: 10A
Rated Insulation Voltage (Ui): 690V (IEC 60947-5-1); 600V (UL); 600V (CSA)
Conventional Free Air Thermal Current (Ith): 10A at 60°C
Irms Rated Making Capacity: 140A AC; 250A DC
Permissible Short-Time Rating: 100A for 1s; 120A for 500ms; 140A for 100ms
Protection Type: GG Fuse 10A
Mechanical Durability: 30 Million Cycles
Minimum Switching Current: 5mA
Minimum Switching Voltage: 17V
Non-Overlap Time: 1.5ms On Energisation And De-Energisation
Insulation Resistance: >10 MOhm
Connections - Terminals: Screw Clamp Terminals, 1 or 2 Cable(s), 1...4mm² Flexible or Rigid (With Or Without Cable End); 2 Cable(s) 1...2.5mm² Flexible With Cable End
Tightening Torque: 1.7N.m
Height: 48mm
Width: 44mm
Depth: 42mm
Net Weight: 0.05kg
Colour: Dark Grey
Environmental Characteristic: Normal Environment
IP Degree Of Protection: IP20 (IEC 60529)
Protective Treatment: TH (IEC 60068)
Ambient Air Temperature For Storage: -60°C To 80°C
Ambient Air Temperature For Operation: -5°C To 60°C
Operating Altitude: 3000m
Standards: EN/IEC 60947-5-1, GB/T 14048.5, EN 50012, UL 60947-5-1, CSA C22.2 No 60947-5-1, IEC 60335-1 Clause 30.2, IEC 60335-2-40 Annex JJ, UL 60335-2-40 Annex JJ
Product Certifications: CB Scheme, UL, CSA, CCC, EAC, UKCA
Warranty (Months): 18